Limit Switch (Mechanical)
- For monitoring mechanical movements and end positions
- Controlling sensor for electronic and mechanical sequences
- registers axial disengaging movements, e.g. on EAS-clutches
Limit Switch (Contactless)
- For measuring and monitoring axial and radial disengaging movements, e.g. on EAS-clutches
- Control sensor for electronic and mechanical sequences
Limit Switch (Contactless, Magnetic Field-resistant)
- For monitoring and measuring axial or radial mechanical movements and adjustments e.g. on EAS-clutches
- Used where strong magnetic fields can influence the function of the proximity switch
Limit Switch (Contactless, with Mounting Flange)
- For monitoring and detecting operating conditions on EAS overload clutches
- Axial movements caused by overload or switching procedures are registered
- For further process controlling (e.g. switch-off)
Limit Switch (Mechanical, Multi-directional)
- For monitoring and measureing axial or radial mechanical movements and adjustments e.g. on EAS-clutches
- Suitable for clutches with a minimum stroke of 1.1 mm with radial actuation and 0.9 mm with axial actuation
EAS-Sm/Zr Control Unit
- For switching, controlling, monitoring and to indicating overload for adjustable EAS-Sm synchronous clutches and EAS-Zr overload clutches
EAS-Sp Control Unit
- For monitoring, controlling and to signal overload on pneumatically adjustable overload clutches with switching functions
Half-wave Rectifiers and Bridge Rectifiers
- Used to connect DC units to alternating voltage supplies, for example electromagnetic brakes and clutches (ROBA-stop, ROBA-quick, ROBATIC), electromagnets, electrovalves, contactors, switch-on safe DC motors, etc
Phase Demodulator
- Used to connect DC units to alternating voltage supplies
- Energise brakes for shorter switching times
ROBA-multiswitch
- Fast acting rectifier
- To connect DC units to alternating voltage supplies, for example electromagnetic brakes and clutches
ROBA-switch
- Fast acting rectifier
- To connect DC consumers to alternating voltage supplies, for example electromagnetic brakes and couplings
ROBA-switch 24V
- 24V fast switching module
- To operate DC consumer units with overexcitation or power reduction, for example electromagnetic brakes and clutches
Spark Quenching Unit
- Voltage limitation according to VDE0580 2000-07, Item 4.6
- Reduction of EMC-disturbance by voltage rise limitation, suppression of switching sparks
- Reduction of brake engagement times by a factor of 2-4 compared to freewheel diodes
ROBA-takt switch gear
- To start, stop and to position by switching and controlling the mayr-clutch-brake units
ROBA-takt Circuit Module
- Used to start and stop mayr ROBA-takt circuit modules and mayr-clutch brake combinations
- For alternating 24 VDC coil switching, if a 24 VDC power supply is available